(11 mm) nut driver or socket wrench. For each series or line of equipment Juniper there are many different kinds components and accessories. We use FedEx, UPS, and US Postal Service as shipping carriers. Page 3: Mx960 Quick Start Description Several types of DPCs are available. This unit of measurement is used for racks, servers, rails, shelves, and more. ZTE ZXONE 9700 Packet OTN. MX960-PREMIUM3-DC Datasheet. Attach an ESD grounding strap to your bare wrist, and connect the other end of the strap to an ESD grounding point. To learn more, please review the Technical Bulletin Product Announcement by following the SKU link in the table below (login required) and see the cause and next steps. The dedicated DPC slots are numbered 0 though 5, and 7 though 11, left to right. MX960 Cabinet Size and Clearance Requirements. user@host# set interfaces fe-1/1/3 description "main router interface". I spent time understanding the fixed configuration MX204. The MX Switch Control Board (SCB-MX) provides control plane functions, chassis management functions, and switch plane functions for MX960, MX480, and MX240 routers. Free essays, homework help, flashcards, research papers, book reports, term papers, history, science, politics 3100 Fite Circle, Suite 104 Sacramento, CA 95827. English. MX960. Qty: Add to Cart. Before you replace an SCB or a Routing Engine, you must take the host subsystem offline. Place the SCB on the antistatic mat. Motherboards. 2. The SDN-enabled MX960 Universal Routing Platform is a high performance, carrier-grade, multiservice edge platform with unprecedented scale for service provider and cloud. Gn knhchopha trcgn kttrong mt rackbnbihocni cc. When you remove an FPC, the router continues to function, although the PIC interfaces installed on the FPC being removed no longer function. The Juniper MX240 router shares many baseline features with other modular MX Series routers, while keeping the size comparatively small at only 5 rack units (RU). 1R2, Common Criteria Evaluated Guide for MX240, MX480, MX960, MX2010, and MX2020 Devices navigate_next. DC power supply;Modular Port Concentrators (MPCs) provide packet forwarding services. 3ad balances traffic across the member links within an aggregated Ethernet bundle based on Layer 3 information carried in the packet, Layer 4 information carried in the packet, or both, or based on session ID data. 3 kg) and consists of one AC appliance inlet, an AC input switch, a fan, and LEDs to monitor the status of the power supply. But the specifications of the MX240 are much higher-performing than all the MX Series’ fixed-configuration. Performance Switching capacity: 9. Beta. Secure the optional ESD jack with the star washer and nut provided in the installation kit. We have sub-branches in United States and United Kingdom. Rich multiservice edge, timing features. • 3U = 5. The router provides. Extended Batteries; PDU (power distribution unit) Rack ATS; Cooling; Power Conditioner; Rack Power Module; Racks and Enclosures; KVM and Accessories ; Search: Search. A. Add To Cart. 45 x 14 x 27. Two types of chassis are available for the MX960 router: MX960, MX480, and MX240 Universal Routing Platforms are modular, chassis-based platforms. The minimum-sized cabinet that can accommodate the router is 482-mm wide and 800-mm deep. Juniper Networks MX Series 5G Universal Routing Platforms process incoming and outgoing packets on several different types of interface modules (also known as line cards). Removing the Power Supplies Before Installing an MX960 Router Without a Lift on page 1 2. Due to its small size, the MX240 supports only two MPC slots. Ships Within Special Order. The MX5's Gigabit Ethernet Modular Interface Card (MIC) includes Junos® Traffic Vision for built-in comprehensive flow monitoring. When supporting 48 PFEs on the MX960, all of these connections on the switch. 1-866-439-2356. : Provide multiple physical interfaces and Packet Forwarding. ODF Distribution Unit; ZTE Optical Transport Network. PDF manual · 408 pages. 1-415-230-4353. To remove a DC power supply (see. High Availability and Redundant Operation. Sell Unit CASE. Offering ultra-high-density 10GbE, 25GbE, 40GbE, 50GbE, 100GbE, and 400GbE connectivity in a space- and power-optimized package, the MX304 delivers 4. Sign In. 5 inches. The private VLAN (PVLAN) feature on MX Series routers allows an administrator to split a broadcast domain into multiple isolated broadcast subdomains, essentially putting a VLAN inside a VLAN. : MX960. Table 2 provides. Figure 1: AC Plug Types. Juniper Networks Mounting Shelves for MX960 Cha. Canada (Français) Cart (0) Sign In ☰The Application Services Modular Line Card (AS MLC) is an X86-based card for MX960, MX480, and MX240 routers to deliver integrated application service solutions. Power & space efficiency – 2 RU. root@# set system host-name host-name. The gateway from segment gateway just relay to this MX. Download. The SDN-ready MX960 3D Universal Edge Router brings high performance, reliability, and scale for service provider and enterprise applications. The MX960 router has 11 dedicated DPC slots and one multifunction slot that supports either a DPC, FPC, or Switch Control Board (SCB). <h2>Used MX960 Routers Feature a Large Frame with Powerful Specifications</h2> <p>Pre-owned Juniper MX960 routers are a long-term solution for advanced. Juniper DPCE X 40GE SFP 40X1GE for MX960 MX480 MX240 Ro on PopScreen. but when a unit is found to be defective during the warranty period, we stand behind that equipment with a thorough Return Merchandise. Let us know what you think. Cover the router with an ESD bag and place the packing foam on top of and around the router. If you provide adequate cooling air and airflow clearance in a cabinet that. 49 (16 U) x 71. Reinstalling the DPCs After Installing the MX960 Router Without a Lift on page 5 5. Buy: Juniper MX960 Ethernet Services Router Chassis. 30 Compliance Statements for EMC Requirements . In many cases, customer support SKUs are. power unit Juniper PWR-FAN-MX960-DC-HC-U (MX960 High Capacity power/cooling. Repeat steps 1-17 for installing power supplies in slots 1, 2, and 3, where present. The SDN-ready MX960 3D Universal Edge Router brings high performance, reliability, and scale to the broadest range of service provider and enterprise applications. 75 inches (44. The MX960 has been proven in the world’s largest service provider, cable, mobile, and data center networks, ofering 12 Tbps of system capacity in support of business and residential broadband services as well as peering and provider edge applications. The MX304 Universal Routing Platform delivers 4. MX480-PREMIUM3-AC. They can operate in one-feed mode or two-feed mode. 5" Depth: 23. Call 415-230-4353. MX480 Router Hardware and CLI Terminology Mapping. (62. Example: Configuring an IRB Interface on a Security Device. MX960 chassis pdf manual download. Juniper Networks MX960 High-Capacity DC Power Supply, Model Number PWR-MX960-4100-DC-S, is to be used with Juniper MX960 Router. Cisco uBR7100 Series Universal Broadband Router Features and Benefits Cost-Effective Integrated DOCSIS- or EuroDOCSIS-Based CMTSUser manual for the Juniper MX960 3D in English. 56 Tbps of system capacity in one-third of a standard telco rack, with support for high-density 10GbE, 40GbE, and 100GbE interfaces, as well as legacy SONET/SDH, ATM, and PDH. 6 mm). . 8"Width17. We would like to show you a description here but the site won’t allow us. It’s large size, 16 rack units (RU), allows it to support up to 12 Modular Port Concentrators (MPC). While annual double- digit traffic growth requires massive resource investments to prevent congestion and accommodate unpredictable. DISCLAIMER PLEASE NOTE: Images, Descriptions, and Titles may not accurately represent the product. give review. Date. The router provides 14. Get it online at a great price with quick delivery. Quantity: ASK MX960-PREMIUM3-DC Price. 1 lb (5. SKU Number CIA2262319. Home /Before you remove a power supply, be aware of the following:The EX4300 switches are single rack unit (1 U) devices that deliver a compact solution for crowded wiring closets and access switch locations where space and power are at a premium. The MX960 router is 16 rack units (RU) tall. Overview and Physical Description. It offers 10. Search. Installing the MX960 Mounting Hardware for Front-Mounting in an Open-Frame Rack | Juniper NetworksJuniper Networks MX960 Filter Tray for High-Cap. Each EX4300 supports standard 40GbE QSFP+ ports which are preconfigured to support high-speed Virtual Chassis backplane connections; on the 1GbE access switches. 8"Width17. The MX960 enables inline MACsec support without performance penalties on 10, 40 GbE and 100 GbE, and delivers 12 Tbps of system capacity in a 12 slot chassis. Controller Cards. Installing an SFP or XFP Transceiver into an MX960 DPC, MPC, MIC, or PIC. 1. 5 Tbps: 1. (11 mm) nut driver or socket wrench. 1–45 rack space units. 45 mm) of vertical space. MX960 RouterKashif Latif 2. Est. 5 Tbps: Power-40 to -72 V DC: DPCs and/or MPCs Per Chassis: Up to 11: Chassis Per Rack: 3: Maximum Weight: 334 lb / 151. On the front rack rails, install cage nuts in the holes specified in the MX960 3D Universal. The MX960 router is 16 rack units (U) tall. . Home /Neobits. 2 cm) deep (from the front to the rear of the chassis). After completing the installation and basic configuration procedures covered in this guide, refer to the Junos OS documentation for information about further software configuration. (44. . in the rack. The rack or cabinet must have an adequate supply of cooling air. After the mounting hardware is installed, proceed to Installing the MX960 Router Using a Mechanical Lift. 56 Tbps of system capacity in one-third of a standard telco rack, with support for high-density 10GbE, 40GbE, and 100GbE interfaces, as well as legacy SONET. 76 kg), or 150 lb (68. To accommodate a single router, the cabinet must be at least 13 U high. A cabinet larger than the minimum requirement provides better airflow and reduces the chance of overheating. Buy: Juniper MX960 Ethernet Services Router Chassis. Juniper routers · Juniper MX960 3D manual. The Juniper PWR-MX960-DC is a high-performance power supply unit designed to power Juniper Networks MX960 routers. Note: Starting with Junos OS Release 15. Three routers can be stacked in a single floor-to-ceiling rack, for increased port density per unit of floor space. It offers 10. Request a quote today!MX960-PREMIUM3-AC Juniper Networks MX-series MX960 router rack mountable. To replace hardware components, you need the tools and parts listed in Table 1. Ultra-high density& throughput in only three rack units. The Juniper MX960 Router is a Scalable Networking Solution Designed to Take On Growth Pre-owned Juniper MX960 routers build on the specifications of less-powerful modular. Page 2 MX960 3D Universal Edge Router Quick Start Compliance Statements for NEBS. The conversion of an MX960 router from AC to DC or DC to AC should be performed with the system completely powered off. 8"Width17. The MX960 (appears to be the biggest version in the MX240, MX480 family). That is 12 Tbps capacity and support of up to. Lenovo ThinkSystem SR570 Rack Servers; Lenovo ThinkSystem SR530 Rack Servers;. Ensure that the pin is seated inside the corresponding hole in the chassis. The rack-mounting hardware for the MX960 router includes: The large mounting shelf for mounting in four-post racks, cabinets, and open-frame racks The small mounting shelf. Internal Item Number: SMITHS-MX960. ODF Distribution Unit; ZTE Optical Transport Network. After completing the installation and basic configuration procedures covered in this guide, refer to the Junos OS documentation for information about further software configuration. Sign In. Configure the name of the router. MFR: MX960BASE-AC-ECM or other Routers & Gateways at Hardware Nation. Use this guide to install hardware and perform initial software configuration, routine maintenance, and troubleshooting for the MX960 5G Universal Routing Platform. Removing an MX960 MIC. Our Solution The 48DCWB-10-2X300-E0 Remote Power Manager / Power Distribution Unit provides (5) high-power outputs (up to 125A rated) from each of (2) 300A rated input terminal blocks. 2 MB] QFX Series [ZIP 56. 1–45 rack space units. Availability: Temporarily Out-of-Stock. Figure 1: AC Plug Types. The chassis installs in many types of racks, including 800-mm deep (or larger) enclosed cabinets, standard 19-in. PDU (power distribution unit) Rack ATS; Cooling; Power Conditioner; Rack Power Module; Racks and Enclosures; KVM and Accessories ; Search: Search. pdf), Text File (. ODF Distribution Unit; ZTE Optical Transport Network. View online (596 pages) or download PDF (13 MB) Juniper MX960, mx960 3D User manual • MX960, mx960 3D PDF manual download and more Juniper online manualsJunos OS Release 20. 25 inches. The three lifters can then move the router to the shipping container. Mx960-Hardware Guide Internet - Free ebook download as PDF File (. Before you remove a power supply, be aware of the following:The Switch Control Board (SCB) framer in MX Series routers supports only the first-generation Synchronization Status Message (SSM) format. 6 kg. Table 2 provides specifications for the high-capacity second-generation PSM. Replacing an MX240 MPC. MX480 Component Redundancy. The checklist in Table 1 summarizes the tasks you must perform when preparing a site for router installation. 8 Tbps of throughput. You must also remove the mounting brackets from the chassis. Repeat steps 1-12 for installing power supplies in slots 1, 2, and 3, where present. content_copy zoom_out_map. date_range 2-Nov-23. MX960 Rack Requirements | Juniper NetworksTable 1 lists the FRUs for the MX960 router. The router internal Ethernet interface connects the Routing Engine with the router’s packet forwarding components. If the output does not display the intended configuration, repeat the instructions in this example to correct the configuration. DPCE-X-40GE-SFP Juniper 40-Port 1GbE Rack mountable Expansion Module. MX960 Universal Router Hardware Guide - Free ebook download as PDF File (. Operating temperature: 0–104°F (0–40°C) at 6000 feet. Figure 1 shows the power supply. 37 x 27. In Junos OS Release 11. Before you remove a power supply, be aware of the following: After powering off a power supply, wait at least 60 seconds before turning it back on. The green OK LED next to the button begins to blink. Beta. System capacity 5. Juniper mx960 3D Pdf User Manuals. The two acoustic covers are designed to reduce the system sound level to comply with the Network Equipment. 8 Tbps of throughput in just two rack units (RU), providing unmatched edge router density and performance while consuming just 0. 8:00AM-4:00PM CST Juniper Networks 1PSRX210-MK rack mounting kit for f 19 rack new in box item includes: only does not include: or anything listed condition: this is a used the original. Our patented clamp design makes installation easy, with no drilling required! Great for various box lengths, as all stands can. Each AC power supply weighs approximately 5. Installing racks ANSI Hardware Installation Manual Figure 15 Securing the rack to the floor (non-seismic qualified installation) 1/2 in. Transceiver. As an example of Juniper's commitment to delivering Ethernet-centric solutions to meet the needs of next-generation networks and services, the MX960 offers unmatched scalability, performance, reliability and QoS for both business and residential services. MFR: MX960-PREMIUM-DC or other Routers & Gateways at Hardware Nation. The carrier-grade MX2008 Universal Routing Platform helps service providers and cloud operators address long-term traffic, subscriber, and services growth. There are just more options available for VLAN manipulation when using SP-style, as well as other functionality that you don't get when using Enterprise configuration style. Reinstalling the SCBs After Installing the MX960 Router Without a Lift on page 4 4. Edge Router Hardware Guide for the large shelf and the spacer bars. Chassis per rack 3. Part Number Smiths Medical MX960. The MX960 Universal Routing Platform with the standard cable manager is 16 rack units (U) tall, or 21 U with the extended cable manager. 7/16-in. For a list of the DPCs supported, see the MX Series Interface Module Reference. in the rack. MX960 3D Universal Edge Router. Align the rear of the MIC with the guides located at the corners of the MIC slot. All major hardware components including the power system, the cooling system, and the control board are fully. MX480BASE-AC Chassis Midplane RE 1-SCB 3 AC PEM, US $ 800 - 1000 / Set, 1000Mbps, Yes, Wi-Fi 802. 4 and later, the output for the show chassis hardware models operational mode command for MX Series devices display the enhanced midplanes FRU model numbers—CHAS-BP3-MX240-S, CHAS-BP3-MX480-S, or CHAS-BP3-MX960-S—based on the router. Two types of. Canada (Français) Cart (0) Sign In ☰Lowest price on Juniper Router Chassis CHAS-BP-MX960-S-A Model: 540-014951 COM8T00CRA. In the DC power configuration, the router contains either two or four DC power supplies (see Figure 1), located at the lower rear of the chassis in slots PEM0 through PEM3 (left to right). Bộ định tuyến mô-đun cung cấp gần 6 Tbps dung lượng hệ thống cho đám mây, khuôn viên, doanh nghiệp, trung tâm dữ liệu, biên nhà cung cấp dịch vụ, cáp và triển khai cốt lõi dịch vụ di động. Product Description Juniper Networks MX-series MX960 - modular expansion base - rack-mountable. The router provides 14 slots that can be populated with up to 12 interface cards and two Switch Control Boards (SCBs) in nonredundant fabric configurations. com: Buy Juniper Networks - MX960-PREMIUM2-AC - Juniper MX960 Router Chassis - 16 - 16U - Rack-mountable - 1 YearTM HIU PHN CNG ROUTER JUNIPER MX960. Junos OS Release 19. Categories . Email. Buy: Juniper MX960 Router Chassis MFR: MX960-PREMIUM2-AC or other Routers & Gateways at Hardware Nation. It offers 10. The MX480 5G Universal Routing Platform is an Ethernet-optimized edge router that provides both switching and carrier-class Ethernet routing. . Example: Configuring Routing Between VLANs on One Switch Using an IRB Interface. Create a management console user account. • The MX960 is ideal for large service provider and cloud networks, cable applications, and mobile service cores. MX480 Craft Interface Description. Chassis per rack: 3. For More Information. Install the router as close as possible to the front of the cabinet so that the cable management brackets just clear the inside of the front door. Rack servers and other hardware designed to be rack-mounted are manufactured in multiples of 1. ODF Distribution Unit; ZTE Optical Transport Network. 6 kg. MX960 Cabinet Airflow Requirements. PN: SCB-MX960-S-G . Canada (Français) Cart (0) Sign In ☰Canada (Français) Cart (0) Sign In ☰The MX960-PSM-HV (HVAC or HVDC) power supplies requires a high current cable assembly when set for 30-A input. 59. M (M, MX) Series Hardware Dates & Milestones. The two acoustic covers are designed to reduce the system sound level to comply with the Network Equipment Building System. MX960 Rack-Mounting Hardware The rack-mounting hardware for the MX960 router includes: The large mounting shelf for mounting in four- post racks,. 4 Rack-Mounting Requirements . Capacity. will be professionally packed and shipped out via UPS to the Lower 48 States. Technical Specifications. Use this guide to install hardware and perform initial software configuration, routine maintenance, and troubleshooting for the MX960 5G Universal Routing Platform. MX960 Field-Replaceable Units;. Before installing the router in a four-post rack or cabinet, install the large mounting shelf, followed by the small mounting shelf. Solutions. (35. content_copy zoom_out_map. Dynamic power. 4R1 or later on the MC-LAG peers. Density – 96 x 10/25 GbE, 48 x 40/50/100, 12 x 400 GbE. Page 2 MX960 3D Universal Edge Router Quick Start Compliance Statements for NEBS. fgdgdgmx960 Hwguide - Scribd. An example of an open-frame rack appears in Figure 1. Several routers can be stacked in a single floor-to-ceiling rack, for increased port density per unit of floor space. Troubleshooting the MX240 MPCs. We provide fast shipping and free tech support. NOTE: Images may not be exact; please check specifications. pdf), Text File (. To install the upper fan tray cover (Figure 1 on page 3): 2 MX960 Acoustic Noise Cover Installation and RemovalGrasp the ejector handles, and slide the SCB about halfway out of the chassis. The Juniper MX960 Router delivers what’s needed for serious service providers, cloud providers, and other data center operators. Installing a router in an upper position in a rack or cabinet requires a lift. 4100W AC Power Supply, Redundant, (Note: AC power cords are sold separately). The multifunction slot is labeled 2/6. 3ad standard. Mx960-Hardware Guide Internet1. The MX960 ServicesMX960 MX480 MX240 MX104 n MX80 3 niversa dg outers Data heet • The MX 2020 and MX2010 are ideal for large service provider and cloud networks, cable applications, and. Dimensions Although the Juniper MX240 is larger than all fixed-configuration MX Series routers, at only 5 rack units (RUs), it’s more compact than the MX480 and MX960. Switch on the dedicated customer site circuit breaker. Switch Control Board, MX960, Spare. Save on Juniper PWR-MX960-4100-AC-R. NEMA L6-20P. Memory. Use this guide to install hardware and perform initial software configuration, routine maintenance, and troubleshooting for the MX480 5G Universal Routing Platform. Call 415-230-4353. Give us a call! Search: Search. The PWR-MX960-DC power supply is hot-swappable, making it easy tOvernight installation of 3 Juniper Networks MX960 routers across 2 London datacenters. This document describes how to remove and replace the acoustic noise covers on a Juniper Networks MX960 Universal Routing Platform. 3R1 . The SDN-enabled MX960 Universal Routing Platform is a high performance, carrier-grade, multiservice edge platform with unprecedented scale for service provider and cloud applications. MX960 Field-Replaceable Units;. Mixing currents can damage the device. The panel width is standardized at 19 inches (482. The MX240 is the Entry-level Modular Router of the MX Series Pre-owned Juniper MX240 routers are the smallest routers with a modular design in the MX Series. 34 MB] General Networking Icons [ZIP 312 KB] Juniper Networks provides an image library for all our logos and product photos. 8 x 27. MX960 Midplane Description ( Mặt phẳng giữa ) Midplane nắm. The rack-mounting hardware for the MX960 router includes: The large mounting shelf for mounting in four-post racks, cabinets, and open-frame racks The small mounting shelf for front-mounting in a four-post rack or cabinet Front-mounting flanges on the front of the chassis for front-mounting in a four-post rack or cabinet The MX960 Universal Routing Platform with the standard cable manager is 16 rack units (U) tall, or 21 U with the extended cable manager. Number of Total Expansion Slots14Ethernet Technology400 Gigabit EthernetRedundant Power Supply SupportedYesCompatible Rack Unit16UForm FactorRack-mountableHeight27. ACX500 indoor unit 2x1GbE (SFP) + 4x1GbE (combo) with single DC power supply, 1 U, temperature hardened, passive cooling, rack mounting options, PoE support, Junos OS ACX500-O-AC ACX500 outdoor unit 3x1GbE (SFP) + 3x1GbE (Cu) with single AC power supply, IP65-compliant for outdoor installation, pole/wall mounting options, no Power over Ethernet. com. 44 cm) behind the router. A rack unit, U or RU is a unit of measurement that describes the height of equipment designed to mount in a 19″ rack. Three routers can be stacked in a single floor-to-ceiling rack, for increased port density per unit of floor space. -13 Hex nut 1/2 in. MX10008 provides 1-Gigabit Ethernet, 10-Gigabit Ethernet, 40-Gigabit Ethernet, 100-Gigabit Ethernet, or 400-Gigabit Ethernet modular solutions that support up to 76. Flex Product Number Description. The Cisco Nexus 7700 Switches are the latest extension to the Cisco Nexus 7000 Series modular switches. Components. 2. Each DC power supply has a single DC input (–48 VDC and return) that requires a dedicated circuit breaker. Internal Item Number: SMITHS-MX960. Address long-term traffic, subscriber & services growth with the space- and power-optimized MX10003 edge router. txt) or read book online for free. Install the router as close as possible to the front of the cabinet so that the cable management brackets just clear the inside of the front door. The MX960 Services The MX960 router is 16 rack units (RU) tall. In many cases, customer support SKUs are. Powered by the same programmable Junos Trio. ls. (91. Upload. Beta. Step 1: Prepare the Site for MX960 Installation. MX240 Modular Port Concentrator (MPC) Description. This PDF manual has 408 pages. Routing Engines, and Switch Control Boards. Desktop Computers. Availability: Temporarily Out-of-Stock. The chassis installs in many types of racks, including 800-mm deep (or larger) enclosed cabinets, standard 19-in. Features NAT support, VPN support, IPv6 support, High Availability, MPLS Fast Reroute (FRR), Switch Fabric Element Redundancy, Quality of Service (QoS), MPLS. The configuration syntax for each type of line card is the same: fpcport . The SDN-ready MX480 Universal Edge Router delivers high performance, reliability, and scalability, for service provider and enterprise applications. Replace the accessory box on top of the packing foam. Power & space efficiency – 2 RU. The first application that network operators can take advantage of is the Junos Content Encore system, a high-throughput, solid state storage platform for media rich content delivery. Juniper NetworksBook Table of Contents. 1-866-439-2356. The SDN-ready MX960 3D Universal Edge Router brings high performance, reliability, and scale to the broadest range of service provider and enterprise applications. MX10008 provides redundancy and resiliency. MX960 RouterKashif Latif 2. Replacing most FRUs requires minimal router downtime. The upper fan tray cover and interface module cover make up the acoustic noise components. 75 inches (44. Examples of the. The MPCs are inserted into a slot in a router. Dimensions. The rack-mounting hardware for the MX960 router includes: • The large mounting shelf for mounting in four-post racks,. 75″ (44. Canada (Français) Cart (0) Sign In ☰One Juniper Networks MX Series router (MX240, MX480, MX960) One Juniper Networks QFX Series switch (QFX10000, QFX5110, QFX5120) Two servers with LAG support; MX Series routers fill the server role in this example. If you install only one host subsystem, we recommend that you install it in slot 0. Fully populated, the MX240 provides a maximum aggregate switch fabric capacity of up to 1. Components. MX480 Component LEDs on the Craft Interface. The private VLAN (PVLAN) feature on MX Series routers allows an administrator to split a broadcast domain into multiple isolated broadcast subdomains, essentially putting a VLAN inside a VLAN. Buy: Juniper MX960 Router Chassis.